AJNR Am J Neuroradiol. 1986 Sep-Oct;7(5):751-6

MR of hemorrhage: a new approach

Edelman RR, Johnson K, Buxton R, Shoukimas G, Rosen BR, Davis KR, Brady TJ.

Abstract

Using a modification of the partial saturation (PS) pulse sequence, we developed an MR method that permits the acquisition of highly T1- and T2-weighted images of the head and body in as little as 10 sec. The PS images, which were acquired at 0.6 T in a series of six patients with acute and subacute hemorrhage, showed a striking reduction in the signal intensity of hemorrhagic lesions. This effect, which is related to bulk magnetic susceptibility variations, was either minimal or absent on conventional T1- and T2-weighted spin-echo (SE) images. Our results suggest that high-field systems are not needed in order to image acute and subacute hemorrhage.

PMID: 3096097